Inspection Standards

  • Episode 4: BioPin's Inspection Standards of First Article Inspection in the Carbon Coating Steps
    Episode 4: BioPin's Inspection Standards of First Article Inspection in the Carbon Coating Steps
    Oct 26, 2026
    In this issue, BioPin will introduce the first-article inspection standards for the coating process, with three different sampling frequencies.   1. Number of inspections per volume: 3; take the average value. Inspection Norm Including : 1) Foil Width Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of w±0.5 mm (refer to the process standards for specific details). 2)Foil Thickness Using a digital micrometer (0.0001), perform uniform sampling along the width direction within the photofoil region according to the sample size, with a tolerance of h ± 0.5 μm (refer to the process specifications for further details). 3)Foil Surface Density Using an electronic balance and a quantitative sampler, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 32.5±1.6g/m²(12μm mill finished aluminum foil)35.23±1.5g/m²(13μm mill finished aluminum foil) (refer to the process standards for further details). 4)Coating Width Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 mm (refer to the process standards for specific details). 5)Blank Space Width on Both Side Edges Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.8 mm (refer to the process standards for specific details). 6)Blank Space Width in the Middle of the Aluminum Foil Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details). 7) Length of Intermittent Coating Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details). 8) Blank Space of Intermittent Coating Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details). 9) Registration Accuracy Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ≤0.8 mm (refer to the process standards for specific details). 10) Alignment Degree on Both Sides Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ≤0.8 mm (refer to the process standards for specific details). 11) Total Surface Density Using an electronic balance, quantitative sampler, and heat gun, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 33.5±1.5g/m²(12μm mill finished aluminum foil)35.86±1.6g/m²(13μm mill finished aluminum foil) (refer to the process standards for further details). 12) Coating Density(Double Sides) Using an electronic balance, quantitative sampler, and heat gun, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 0.7±0.2 g/m²(refer to the process standards for further details). 13) Total Thickness Using a digital micrometer(0.0001), perform uniform sampling within the measurement area according to the sample size, with a standard of (base aluminum foil’s thickness+2μm )±0.8  (refer to the process standards for specific details). 14) Carbon Coated Foil Resistance Using an electrode resistance tester, Wind a flat, carbon-coated sample measuring approximately 50 × 50 mm for sampling, with a standard of < 5.0 mΩ (refer to the process standards for specific details). 15) Coating Adhesion Using 3M Madhesive tape, Wind a flat, carbon-coated sample measuring approximately 50 × 50 m for sampling, with a standard of Grade B or above 16) NMP Resistance Wiping Testing Using medical cotton swabs and NMP solution, wind a flat, carbon-coated sample measuring approximately 300 × 300 mm for sampling, with a standard of the coating not falling off when bent 5cm each time for 200 times.   2. Number of Inspections Per Volume: 5; Take the Average Value. Inspection Norm Including : 1) Tensile Strength Using a sample holder (15mm) and a tensile testing machine, feed flat samples measuring approximately 15m × 150m, with a standard value of ≥230 MPa (refer to the specific process standards for further details). 2) Elongation Using a sample holder (15mm) and a tensile testing machine, feed flat samples measuring approximately 15m × 150m, with a standard value of ≥2.5% (refer to the specific process standards for further details).   3. Roll/First Article 1) Appearance Using visual inspection, perform a uniform coating sample, with a standard that the surface of the aluminum foil should be smooth and clean. The aluminum foil rolls should be wound without any serious creases, bulges, indentations, or damage. 
    Read More
inquiry_img
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Contact Us: peng@biopin.vip

home

products

WhatsApp

Contact Us