Episode 2: BioPin's Inspection Standards During Precision Cutting Steps
Oct 13, 2026
In this issue, BioPin will introduce the inspection standards between precision cutting steps, including first-piece inspection, finished product inspection, and packaging inspection.
Part 1:First-Piece Inspection
In this part, the sampling frequency is as follows:1 test per roll / per first sample (number of tests per roll: 3 tests, average value taken).
Inspection Norm Including :
1) Foil Width
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of w±0.5 mm (refer to the process standards for specific details).
2)Foil Thickness
Using an electronic balance and a quantitative sampler, perform uniform sampling along the width direction within the photofoil region according to the sample size, with a standard of h ± 0.5 μm (refer to the process specifications for further details).
3)Foil Surface Density
Using an electronic balance and a quantitative sampler, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a tolerance of ±5% relative to σ (refer to the process standards for further details).
4)Dyne Value
Using a Dyne Pen, Wind up a flat aluminum foil sample measuring approximately 100 × 100 mm, with a standard of ≥31dyn/cm.
5)Tensile Strength
Using a sample holder (15 mm) and a tensile testing machine, feed flat samples measuring approximately 15 m × 150 m, with a standard value of ≥230 MPa (refer to the specific process standards for further details).
6)Elongation Rate
Using a sample holder (15 mm) and a tensile testing machine, feed flat samples measuring approximately 15 m × 150 m, with a standard value of ≥2.5% (refer to the specific process standards for further details).
Part 2:Finished Product Inspection.
In this part, The sampling frequency is as follows:1 test / 6 rolls / finished product (3 tests per roll; average value taken).
Inspection Norm Including :
1) Foil Width
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of w±0.5 mm (refer to the process standards for specific details).
2)Foil Thickness
Using micrometer (0.0001 mm resolution) , perform uniform sampling along the width direction within the photofoil region according to the sample size, with a standard of h ± 0.5 μm (refer to the process specifications for further details).
3)Foil Surface Density
Using an electronic balance and a quantitative sampler, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a tolerance of ±5% relative to σ (refer to the process standards for further details).
4)Dyne Value
Using Dyne Pen, Wind up a flat aluminum foil sample measuring approximately 100 × 100 mm.
with a standard of ≥31dyn/cm.
Part 3: Packaging Inspection
In this part, The sampling frequency is full inspetion and totally depend on visual inspetion.
1) Packaging Method
The surface of the carbon-coated aluminum foil roll is wrapped with protective film, followed by an outer layer of pearl cotton. A prominent unrolling arrow mark is affixed to the pearl cotton layer; the outermost layer is sealed with an F-material film, and the outer packaging consists of wooden crates.
2) Packaging Label
The outer packaging shall indicate the production date, product model, production batch, and environmental protection labeling (including the shipment report).
3) Packaging Box
The packaging box shall not exhibit damage, severe contamination, or moisture damage.
Above all is all the inspection norm and relative inspection standards during BioPin’s precision cutting step. In the next blog, we will continue share BioPin’s slurry inspection norm details which is the key step of the production flowchart.
Read More