Episode 4: BioPin's Inspection Standards of First Article Inspection in the Carbon Coating Steps
Oct 26, 2026
In this issue, BioPin will introduce the first-article inspection standards for the coating process, with three different sampling frequencies.
1. Number of inspections per volume: 3; take the average value.
Inspection Norm Including :
1) Foil Width
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of w±0.5 mm (refer to the process standards for specific details).
2)Foil Thickness
Using a digital micrometer (0.0001), perform uniform sampling along the width direction within the photofoil region according to the sample size, with a tolerance of h ± 0.5 μm (refer to the process specifications for further details).
3)Foil Surface Density
Using an electronic balance and a quantitative sampler, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 32.5±1.6g/m²(12μm mill finished aluminum foil)35.23±1.5g/m²(13μm mill finished aluminum foil) (refer to the process standards for further details).
4)Coating Width
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 mm (refer to the process standards for specific details).
5)Blank Space Width on Both Side Edges
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.8 mm (refer to the process standards for specific details).
6)Blank Space Width in the Middle of the Aluminum Foil
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details).
7) Length of Intermittent Coating
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details).
8) Blank Space of Intermittent Coating
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details).
9) Registration Accuracy
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ≤0.8 mm (refer to the process standards for specific details).
10) Alignment Degree on Both Sides
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ≤0.8 mm (refer to the process standards for specific details).
11) Total Surface Density
Using an electronic balance, quantitative sampler, and heat gun, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 33.5±1.5g/m²(12μm mill finished aluminum foil)35.86±1.6g/m²(13μm mill finished aluminum foil) (refer to the process standards for further details).
12) Coating Density(Double Sides)
Using an electronic balance, quantitative sampler, and heat gun, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 0.7±0.2 g/m²(refer to the process standards for further details).
13) Total Thickness
Using a digital micrometer(0.0001), perform uniform sampling within the measurement area according to the sample size, with a standard of (base aluminum foil’s thickness+2μm )±0.8 (refer to the process standards for specific details).
14) Carbon Coated Foil Resistance
Using an electrode resistance tester, Wind a flat, carbon-coated sample measuring approximately 50 × 50 mm for sampling, with a standard of < 5.0 mΩ (refer to the process standards for specific details).
15) Coating Adhesion
Using 3M Madhesive tape, Wind a flat, carbon-coated sample measuring approximately 50 × 50 m for sampling, with a standard of Grade B or above
16) NMP Resistance Wiping Testing
Using medical cotton swabs and NMP solution, wind a flat, carbon-coated sample measuring approximately 300 × 300 mm for sampling, with a standard of the coating not falling off when bent 5cm each time for 200 times.
2. Number of Inspections Per Volume: 5; Take the Average Value.
Inspection Norm Including :
1) Tensile Strength
Using a sample holder (15mm) and a tensile testing machine, feed flat samples measuring approximately 15m × 150m, with a standard value of ≥230 MPa (refer to the specific process standards for further details).
2) Elongation
Using a sample holder (15mm) and a tensile testing machine, feed flat samples measuring approximately 15m × 150m, with a standard value of ≥2.5% (refer to the specific process standards for further details).
3. Roll/First Article
1) Appearance
Using visual inspection, perform a uniform coating sample, with a standard that the surface of the aluminum foil should be smooth and clean. The aluminum foil rolls should be wound without any serious creases, bulges, indentations, or damage.
Read More