Episode 5: BioPin's Inspection Standards During Carbon Coating Process Stage
Nov 02, 2026
In this issue, BioPin will introduce the inspection standards for the carbon coating process stage. There are three different sampling frequencies.
1. 1 Time/ 3 Rolls/ Processing Step (Number of Inspections Per Volume: 3; Take the Average Value)
Inspection Norm Including :
1) Burrs and Indentation
Using optical microscope, the sample length at the end of the roll is approximately 1.5 meters. with a standard of Rip length ≤ 50 μm, ≤ 10 features per 500 mm spacing; spacing greater than 50 m; notch depth ≤ 8 μm; ≤ 5 features per 500 m spacing; spacing greater than 100 m
2) Foil Thickness
Using a digital micrometer(0.0001), perform uniform sampling along the width direction within the photofoil region according to the sample size, with a standard of base aluminum foil’s thickness ± 0.5 μm (refer to the process specifications for further details).
3) Foil Surface Density
Using an electronic balance and a quantitative sampler, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with the standard of 32.5±1.6g/m²(12μm bare aluminum foil) or35.23±1.5g/m²(13μmbare aluminum foil) (refer to the process standards for further details).
4) Foil Width
Using a film ruler, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a tolerance of ±0.5 m (refer to the process standards for specific details).
5) Coating Width
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 mm (refer to the process standards for specific details).
6) Blank Space Width in the Middle of the Aluminum Foil
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details).
7) Blank Space Width on Both Side Edges
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.8 m(refer to the process standards for specific details).
8) Registration Accuracy
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ≤0.8 mm (refer to the process standards for specific details).
9) Coating Medium State
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ≤0.8 mm (refer to the process standards for specific details).
10) Length of Intermittent Coating
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details).
11) Blank Space of Intermittent Coating
Using a film ruler, perform uniform sampling within the measurement area according to the sample size, with a tolerance of ±0.5 m (refer to the process standards for specific details).
12) Surface Density
Using an electronic balance, quantitative sampler, and heat gun, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 33.5±1.5g/m²(12μm mill finished aluminum foil)35.86±1.6g/m²(13μm mill finished aluminum foil)(refer to the process standards for further details).
13) Total Thickness
Using a digital micrometer(0.0001), perform uniform sampling within the measurement area according to the sample size, with a standard of (base aluminum foil’s thickness+2μm )±0.8 (refer to the process standards for specific details).
14) Coating Density(Double Sides)
Using an electronic balance, quantitative sampler, and heat gun, perform uniform sampling along the width direction within the photofoil area according to the specified sample quantity, with a standard of 0.7±0.2 g/m²(refer to the process standards for further details).
2. 1 Time/ 3 Rolls/ Processing Step (Number of Inspections Per Volume: 5; Take the Average Value).
Inspection Norm Including :
1) Tensile Strength
Using a sample holder (15 mm) and a tensile testing machine, feed flat samples measuring approximately 15 m × 150 m, with a standard value of ≥230 MPa (refer to the specific process standards for further details).
2) Elongation
Using a sample holder (15 mm) and a tensile testing machine, feed flat samples measuring approximately 15 m × 150 m, with a standard value of ≥2.5% (refer to the specific process standards for further details).
3. Full Inspection
Inspection Norm Including :
1) Roll Length
Check using a meter.
Quality control at the carbon coating stage is critical to the final performance of carbon-coated aluminum foil. By following this set of inspection standards, we can reliably manage defects. In our next episode, BioPin will bring you another quality inspection standard related to battery foil production.
Read More